Fault status – Rockwell Automation 2098-DSD-xxx Ultra3000 Digital Servo Drives with DeviceNet User Manual

Page 91

Advertising
background image

Publication 2098-RM004A-EN-P – August 2002

Programming Reference

2-75

123

Get

Fault Status

DWORD

4

The Fault Status and Extended Fault Status
parameters provide the present state of the possible
fault conditions.
Bit 0 = Absolute Feedback Memory
(Nonvolatile Memory Endurance Exceeded)
Bit 1 = Absolute Feedback Overspeed
(Position Change Exceeds Position Rollover / 2)
Bit 2 = Absolute Feedback Range Exceeded
Bit 3 = Motor Overtemp
Bit 4 = IPM Fault
Bit 6 = Encoder Channel B Line Break
Bit 7 = Encoder Channel A Line Break
Bit 8 = Bus Undervoltage
Bit 9 = Bus Overvoltage
Bit 10 = Bad Hall State
Bit 11 = Home Search Failed
Bit 12 = Home Position Outside Limits
Bit 13 = Network Communication
Bit 14 = Electrical Cycle
Bit 16 = User Current Fault
Bit 17 = Motor Overspeed
Bit 18 = Following Error
Bit 19 = Motor Encoder
Bit 20 = Auxiliary Encoder
Bit 21 = Motor Thermal Protection
Bit 22 = IPM Thermal Protection
Bit 23 = Excessive Velocity Error
Bit 24 = Sensor Unassigned
Bit 25 = Motor Speed Limit
Bit 26 = Axis Not Homed
Bit 27 = Motor Parameter Error
Bit 28 = Excessive Encoder Output Frequency
Bit 29 = Encoder Communication
Bit 30 = Encoder Data Error
Bit 31 = Sincos Encoder Frequency Too High

124

Get

Extended Fault
Status

WORD

2

The Fault Status and Extended Fault Status
parameters provide the present state of the possible
fault conditions.
Bit 0 = Position Outside Modulus
(Absolute Position Exceeds Position Rollover
Bit 1 = Ground Short Circuit
Bit 2 = Soft-Starting Fault
Bit 3 = Internal Overtemperature
Bit 4 = AC Input Phase Loss
Bit 5 = Reserved
Bit 6 = Self-sensing Error

Parameter Object,
Instances ID = 1- 1059

Parameter
Instance

Access
Rule

Parameter
Name

Data
Type

Data Size
(Bytes)

Units /
Scale

Description