Publication 2098-RM004A-EN-P – August 2002

Programming Reference

2-81

202

Set

Electrical Cycle
Length

UINT

2

meter /
10000

Length of an electrical cycle for a linear motor
(Active if Parameter Instance 195 = 1).
Range: 100 to 10000
Default: 300

Note: Set is not allowed if the drive is enabled.

203

Set

Integral Limits

USINT

1

Indicates whether the motor provides built in
feedback for travel limits.
0 - No (default)
1 - Yes

Note: Set is not allowed if the drive is enabled.

204

Set

Rated Motor
Voltage

UINT

2

Volts

The rated voltage of the motor, in units of AC RMS
Volts.
Range: 100 to 1000
Default: 230

Note: Set is not allowed if the drive is enabled.

205

Set

Motor Resistance UINT

2

Ohms /
256

The phase to phase resistance of the motor stator.
Range: 1 to 65535
Default: 998

Note: Set is not allowed if the drive is enabled.

206

Set

Motor Inductance UINT

2

mH /
256

The phase-phase inductance of the motor stator.
Range: 1 to 65535
Default: 6144

Note: Set is not allowed if the drive is enabled.

207

Set

Flux Saturation 0

USINT

1

The motor flux saturation value at 12.5% of motor
peak current. The value is scaled so that 255
indicates no saturation, and 64 indicates 75%
saturation.
Range: 1 to 255
Default: 255

Note: Set is not allowed if the drive is enabled.

208

Set

Flux Saturation 1

USINT

1

The motor flux saturation value at 25% of motor
peak current. The value is scaled so that 255
indicates no saturation, and 64 indicates 75%
saturation.
Range: 1 to 255
Default: 255

Note: Set is not allowed if the drive is enabled.

Parameter Object,
Instances ID = 1- 1059

Parameter
Instance

Access
Rule

Parameter
Name

Data
Type

Data Size
(Bytes)

Units /
Scale

Description