Connection object (classid05h), Connection object (class id 05 – Rockwell Automation 2098-DSD-xxx Ultra3000 Digital Servo Drives with DeviceNet User Manual

Page 61

Advertising
background image

Publication 2098-RM004A-EN-P – August 2002

Programming Reference

2-45

Connection Object
(Class ID 05

H

)

The Connection Object manages the internal resources associated
with both I/O and Explicit Messaging Connections. The specific
instance generated by the Connection Class is referred to as a
Connection Instance or a Connection Object. A Connection Object
within a particular module actually represents one of the end-points of
a connection.

DeviceNet Connection Object,
Instance ID = 1 - 10

Instance
ID

Instances

1

Group 2 Explicit Message Connection

2

Poll I/O Connection

4

Change-of-State or Cyclic I/O Connection

6-10

Group 3 Explicit Message Connections

DeviceNet Connection Object,
Attributes of Instances ID = 1 - 10 /

Attr ID

Access
Rule

Attribute
Name

Data Type

Description

1

Get

State

USINT

State of the Connection

2

Instance Type

I/O or Message Connection

3

Transport_class_trigger

BYTE

Defines the behavior of the Connection

4

Produced_connection_id

UINT

CAN identifier to transmit on

5

Consumed_connection_id

CAN identifier to receive on

6

Initial_comm_characteristics

BYTE

Defines the Message Group(s) associated with this
Connection

7

Produced_connection_size

UINT

Maximum number of bytes transmitted across this
Connection

8

Consumed_connection_size

Maximum number of bytes received across this
Connection

9

Set

Expected_packet_rate

Defines timing associated with this Connection

12

Watchdog_timeout_action

USINT

Defines how to handle Inactivity/Watchdog timeouts

13

Get

Produced_connection_path_
length

UINT

Number of bytes in the produced_connection_path
attribute

14

Produced_connection_path

EPATH

Specifies the Application Object whose data is to be
produced by this Connection object

15

Consumed_connection_path_len
gth

UINT

Number of bytes in the Consumed_connection_path
attribute

16

Consumed_connection_path

EPATH

Specifies the Application Object(s) that are to receive
the data consumed by this Connection

17

Set

Production_inhibit_time

UINT

Defines minimum time between new data production
for COS connections.

Advertising