42

Set

Positive Decel
Distance

DINT

4

Cnts

The distance that an axis will travel when an
overtravel limit has been reached in the positive
direction.
Range: 0 to 0x7fffffff
Default: 0

Note: This parameter instance is not available to
non-indexing drives. If invoked, a non-indexing drive
returns Reserved as the parameter name.

43

Set

Negative Decel
Distance

DINT

4

Cnts

The distance that an axis will travel when an
overtravel limit has been reached in the negative
direction.
Range: 0 to 0x7fffffff
Default: 0

Note: This parameter instance is not available to
non-indexing drives. If invoked, a non-indexing drive
returns Reserved as the parameter name.

44

Set

Zero Speed Limit

UDINT

4

Cnts /
Sec

A +/- range, or window, around zero velocity. If the
motor feedback velocity falls within this range, the
Zero Speed flag will be (or remain) set.
Range: 0 to 0x7fffffff
Default: 500

45

Set

Speed Window

UDINT

4

Cnts /
Secs

A +/- range, or window, around the velocity
command. If the motor feedback velocity falls within
this range, the Speed Window flag will be (or
remain) set.
Range: 0 to 0x7fffffff
Default: 1000

46

Set

Up to Speed

UDINT

4

Cnts /
Secs

If the motor feedback velocity is greater than or
equal to this value, the Up to Speed flag will be (or
remain) set.
Range: 0 to 0x7fffffff
Default: 100000

47

Set

Position Window
Size

UDINT

4

Cnts

The maximum amount of position error which will
permit the In Position and the In Position Window
flags to be (or remain) set.
Range: 0 to 0x7fffffff
Default: 20

48

Set

Position Window
Time

USINT

1

mSec

The minimum length of time the position error must
be less than the Position Window Size value, for the
In Position and the In Position Window flags to be (or
remain) set.
Range: 1 to 255
Default: 20

Parameter Object,