Rockwell Automation 2098-DSD-xxx Ultra3000 Digital Servo Drives with DeviceNet User Manual

Page 81

Advertising
background image

Publication 2098-RM004A-EN-P – August 2002

Programming Reference

2-65

75

Set

Maximum
Encoder Output
Frequency

USINT

1

The encoder output frequency limit. This parameter
is active only if Divided or Interpolated is selected as
the Encoder Output Signal.
0 - 500 kHz (default)
1 - 1 MHz
2 - 4 MHz
3 - 8 MHz

76

Set

Marker Output
Gating

USINT

1

Allows the drive to produce and use a more precise
marker signal.
0 - Not Gated - The drives uses and outputs the
normal marker input as received from the encoder.
(default)
1 - Gated with A and B - The marker output of the
drive is the logical AND of the marker input from the
encoder and the A and B inputs. This produces a
more precise marker signal for homing.

77

Set

Auxiliary Encoder
Load Count

UINT

2

Cnts

The Auxiliary Encoder Motor Count and Auxiliary
Encoder Load Count param
eters specify the ratio of
encoder counts between the motor encoder and the
load encoder. The parameters are active only if the
The Position Feedback Source is selected to be
Auxiliary Encoder.
Range: 1 to 32767
Default: 1

78

Set

Auxiliary Encoder
Motor Count

INT

2

Cnts

The Auxiliary Encoder Motor Count and Auxiliary
Encoder Load Count param
eters specify the ratio of
encoder counts between the motor encoder and the
load encoder. The parameters are active only if the
Position Feedback Source is selected to be Auxiliary
Encoder.
Range: -32767 to 32767
Default: 1

79

Set

Auxiliary Encoder
Type

USINT

1

The type of auxiliary encoder.
0 - Rotary Encoder (default)
1 - Linear Encoder

80

Set

Auxiliary Encoder
Lines/Rev

UINT

2

Auxiliary encoder lines per revolution. This
parameter is used only if the auxiliary encoder is a
rotary encoder.
Range: 100 to 64000
Default: 2000

81

Set

Auxiliary Encoder
Lines/ Meter

UDINT

4

Auxiliary encoder lines per meter of travel. This
parameter is used only if the auxiliary encoder is a
linear encoder.
Range: 4000 to 10000000
Default: 10000

Parameter Object,
Instances ID = 1- 1059

Parameter
Instance

Access
Rule

Parameter
Name

Data
Type

Data Size
(Bytes)

Units /
Scale

Description

Advertising