Programming Reference

2-69

99

Set

Analog Output
Scale

INT

2

The analog output scale in units per volt. The units is
dependent on the signal selected by the Parameter
98 - Analog Output Configuration. Parameter 110 -
Analog Output Position Scale is used to scale the
analog output if a position signal is selected and the
Analog Output Scale is zero.
Range: -32767 to 32767
Default: 0

100

Set

Analog Output
Offset

INT

2

mV

The offset applied to the analog output.
Range: -10000 to 10000
Default: 0

101

Set

Override Analog
Output

USINT

1

The analog output override control flag determines if
you can write to the analog output directly. The
Override Analog Output setting is not saved in
nonvolatile memory.
0 - Normal (default)
1 - Override

102

Set

Analog Output
Override

INT

2

mV

Sets the analog output value when Parameter 101,
Override Analog Output is set to 1 - Override. The
Analog Output Override setting is not saved in
nonvolatile memory.
Range: -10000 to 10000
Default: 0

103

Set

User Current
Fault

UINT

2

Amps /
128

The current level that will generate a fault when
exceeded by the average current. The drive
automatically protects itself and the motor when the
average current exceeds the drive or motor current
ratings, and this protection cannot be disabled.
However, you can specify a lower current fault level
with this parameter.
Range: 0 to 32767
Default: 32640

104

Set

User Velocity
Limit

UDINT

4

Cnts /
Sec

The minimum velocity that will generate a User
Velocity fault. The drive automatically protects the
motor from exceeding its ratings, and this protection
cannot be disabled. However, you can specify a
lower velocity fault level with this parameter.
Range: 0 to 0x7fffffff
Default: 100000

105

Set

User Velocity
Fault

USINT

1

Determines if the User Velocity fault detection is
enabled (turned on) or disabled.
0 - Disable (default)
1 - Enable

106

Set

Velocity Error
Limit

USINT

1

% of
max
motor
speed

The minimum velocity error which triggers the
Velocity Error fault.
Range: 1 to 100
Default: 25

Parameter Object,
Instances ID = 1- 1059

Parameter
Instance

Access
Rule

Parameter
Name

Data
Type

Data Size
(Bytes)

Units /
Scale

Description