10 – testing devices, Testing zones, valves, and bicoders – Baseline Systems BaseStation 1000 User Manual

Page 102

Advertising
background image

BaseStation 1000 Irrigation Controller Manual

10 – Testing Devices

The BaseStation 1000 has built-in features for testing zones, valves, biCoders and biSensors. These

tests help you isolate and identify components and devices that are not working properly so you

know what needs to be repaired.

Testing Zones, Valves, and biCoders

When you test a zone, the controller verifies the communication between the controller and the

valve biCoder. The controller activates the solenoid and measures the current and voltage. It

deactivates the solenoid, and measures the voltage drop between the controller and the valve

biCoder.

1. Press the Test button. The Test menu displays.

2. If the Test Zone option is highlighted, press the OK button to select it. If Test Zone is not

highlighted, press the  or  button to highlight it, and then press the OK button. The Test

Zone screen displays.

3. Press the  or  button to select the zone number that you want to test.

4. Press the OK button to test the zone.

The valve will activate for less than a second

to measure the voltage and current through

the valve solenoid. This test will return the

status of the valve, the biCoder serial

number, the solenoid current, the solenoid

voltage, the two-wire voltage drop, and the

version of the two-wire device. If any zones

or programs are running when the test is activated, watering will pause for 10 minutes.

5. Repeat steps 3 and 4 until you have tested all the zones that you wish to test.

6. When you have finished viewing the test results, press the RUN button to return to the Run

menu.

Refer to the following table for possible self-test statuses along with causes and suggestions for

resolving the issues.

Self-test

status

Causes/Action

Open circuit

Wire connection between the valve biCoder and the valve solenoid is

broken – repair wire connections.

Valve solenoid is broken – replace solenoid.

Page 96