To set a moisture start condition, E 42 – Baseline Systems BaseStation 1000 User Manual

Page 48

Advertising
background image

BaseStation 1000 Irrigation Controller Manual

To Set a Moisture Start Condition

Baseline’s biSensor moisture sensor is a reliable device for measuring moisture levels in the root

zone of plants and then sending that data to the controller. You can set a moisture start condition

for a program that will cause the program to start based on a specified soil moisture reading. You

can also use a moisture sensor to monitor the level of water in a pond or cistern and then

automatically start a program based on the water level.

For suggestions on programming your controller for a moisture start condition, refer to Tips for

Setting Up Common Configurations on page 106.

Note: To use a moisture start condition, you must have one or more soil moisture sensors installed

and assigned. Refer to Searching for and Assigning Soil Moisture Sensors on page 30.

1. Press the Program Setup button. The Program Setup menu displays.

2. If the program that you want to modify displays in the upper-left corner of the screen,

continue to step 3. Otherwise, press the PRG button until the program that you want to

modify displays in the upper-left corner of the screen.

Note: To move backwards in the list of programs, press and hold the PRG button, and then

press the button repeatedly.

3. Press the  button to highlight the Setup Prg. Start option, and then press the OK button.

The Setup Prg. Start screen displays the list of start conditions.

4. Press the  button to highlight the Moisture Start option, and then press the OK button. A

checkmark displays next to the Moisture Start option.

5. Press the  button to configure the moisture start settings.

6. Notice that the serial number for one of

your soil moisture sensors is highlighted in

the Moisture field. If this is the serial

number for the sensor installed in the area

that this program will water, no change is

required. If you need to assign a different

soil moisture sensor to the program, press

the + or button to select a different serial

number.

7. Press the  button to highlight the Limit field, and then perform one of the following:

To manually set the limit, press the + or button to change the number in the field.

Depending on how you are using the moisture sensor, this number represents either the

upper or lower limit.

To have the controller set the limit based on a calibration, leave the default settings in

the Limit field, and then enable the calibration as described in step 10 below.

Note: In the Limit field, the value in parentheses is the most current reading from the soil

moisture sensor. Keep in mind that the sensor is read every 10 minutes.

Page 42

Advertising