Changing the drive level for a device – Baseline Systems BaseStation 1000 User Manual

Page 34

Advertising
background image

BaseStation 1000 Irrigation Controller Manual

6. Press the + or button to change the gallons per minute (gpm) for the zone.

Note: To rapidly increase or decrease the value, press and hold the + button or the button.

7. Press the  button to move to the Drive Level field.

Note: Refer to Changing the Drive Level for a Device on page XX.

8. Continue until you have configured the settings for all your zones.

Changing the Drive Level for a Device

If you have a solenoid on your system that turns on but does not stay on, you might need to adjust

the drive level for the biCoder that is connected to that zone. You can adjust the drive level value

from a minimum of 1 to a maximum of 3 to accommodate for solenoids with different power

requirements.

1. Navigate to the Zone Device Setup screen by following the instructions in the Setting Up

Zones topic on page XX.

2. Press the  button to move to the Drive Level field.

3. Press the OK button to read the current drive level of the device.

4. When the number displays in the Drive Level field, press the + or button to change the

setting.

Note: Number 1 is the minimum drive level and 3 is the maximum.

5. Continue until you have changed the drive level for all devices as needed.

Searching For and Assigning Master Valve and Pump Start

biCoders

1. Press the Search & Assign button. The Search & Assign menu displays.

2. Press the  or  button to highlight the MV/Pump option, and then press the OK button to

select it. The MV/Pump screen displays.

3. If the Device Assignment option is highlighted, press the OK button to select it. If Device

Assignment is not highlighted, press the  or  button to highlight it, and then press the OK

button. The MV/Pump Assignment screen displays.

4. When the Search option in the Action column is highlighted, press the OK button to search

for master valve or pump start biCoders.

When the controller finds the devices, their serial numbers display in the Action column.

5. Press the  or  button to move through the list of devices in the Action column. Highlight

the serial number of the device that you want to assign to a master valve or pump start.

6. Press the  button to move to the MV/Pump column.

Page 28