Testing flow sensors, Testing event switches – Baseline Systems BaseStation 1000 User Manual

Page 106

Advertising
background image

BaseStation 1000 Irrigation Controller Manual

Testing Flow Sensors

1. Press the Test button. The Test menu displays.

2. Press the  or  button to highlight the Test Flow Sensor option, and then press the OK

button. The Test Flow Sensor screen displays.

3. Press the  or  button to select the flow sensor number that you want to test.

4. Press the OK button to test the flow sensor.

This test returns the status of the flow sensor,

the flow sensor serial number, the flow rate,

the total water usage, the two-wire voltage

drop, and the version of the device. If any

zones or programs are running when the test

is activated, watering will pause for 10

minutes.

5. Repeat steps 3 and 4 until you have tested all the flow sensors that you wish to test.

6. When you have finished viewing the test results, press the RUN button to return to the Run

menu.

Testing Event Switches

1. Press the Test button. The Test menu displays.

2. Press the  or  button to highlight the Event Switch option, and then press the OK button.

The Test Event Switch screen displays.

3. Press the  or  button to select the event switch number that you want to test.

4. Press the OK button to test the event switch.

This test returns the status of the device, the

device serial number, the switch state, the

two-wire voltage drop, and the version of the

device. If any zones or programs are running

when the test is activated, watering will

pause for 10 minutes.

5. Repeat steps 3 and 4 until you have tested all the event switches that you wish to test.

6. When you have finished viewing the test results, press the RUN button to return to the Run

menu.

Page 100