Manually running individual zones by program – Baseline Systems BaseStation 1000 User Manual

Page 73

Advertising
background image

BaseStation 1000 Irrigation Controller Manual

6. Press the  button to highlight the zone that you want to start or stop, and then press the OK

button.

Any zone that is started with this option shows the runtime countdown to the right of the

zone number. The zones that are not running show Done as their status. If the Max

Concurrent field was set to 1 on the previous screen and you start more than one zone on this

screen, the status of the additional zones is set to Waiting.

IMPORTANT NOTE!

If you press a button on the controller to leave this screen while a manual

run is in progress, the manual run will stop.

Manually Running Individual Zones by Program

You can set the manual runtime between 1 second and 18 hours.

1. Press the Manual Run button. The Manual Run menu displays.

2. Press the  or  button to highlight Run Prg Zone(s), and then press the OK button. The Run

Prg Zone(s) screen displays.

3. If the program that you want to run zones for displays in the upper-left corner of the screen,

continue to step 4. Otherwise, press the PRG button until the program that you want displays

in the upper-left corner of the screen.

Note: To move backwards in the list of programs, press and hold the PRG button, and then

press the button repeatedly.

4. If you want to allow more than one zone to run at one time during the manual run, press the

button to highlight Max Concurrent, and then press the + or button to change the

number.

5. If you want to delay the start of the manual run, press the  button to highlight Start Delay.

Notice that the minutes placeholder is highlighted.

To move to the hour placeholder, press the  button.

To move to the seconds placeholder, press the  button.

To change the time, press the + or button.
Note: To rapidly increase or decrease the value, press and hold the + button or the

button.

6. If you want a delay between the zones of the manual run, press the  button to highlight

Zone Delay. Notice that the minutes placeholder is highlighted.

Note: If the Max Concurrent field is set to more than 1, the Zone Delay field does not display.

To move to the hour placeholder, press the  button.

To move to the seconds placeholder, press the  button.

To change the time, press the + or button.
Note: To rapidly increase or decrease the value, press and hold the + button or the

button.

Page 67

Advertising