Testing master valve and pump devices – Baseline Systems BaseStation 1000 User Manual

Page 103

Advertising
background image

BaseStation 1000 Irrigation Controller Manual

Short circuit

Wire connection between the valve biCoder and the valve solenoid is

shorted together – repair wire connections.

Valve solenoid is broken – replace solenoid.

No response

Two-wire connection to the valve biCoder is broken – repair wire and

connections to the valve biCoder.

Two-wire voltage loss is too high – check other devices in same vicinity

for high two-wire voltage loss – repair high resistance connections

between controller and devices.

Valve biCoder is damaged – remove biCoder and move it directly to the

controller to test its ability to communicate.

Do a device search to repair any address problems.

Testing Master Valve and Pump Devices

When you test a master valve and/or pump device, the controller verifies the communication

between the controller and the device. The controller activates the solenoid and measures the

current and voltage. It deactivates the solenoid, and measures the voltage drop between the

controller and the device.

1. Press the Test button. The Test menu displays.

2. Press the  or  button to highlight the Test MV/Pump option, and then press the OK

button. The Test MV/Pump screen displays.

3. Press the  or  button to select the master valve and/or pump device number that you

want to test.

4. Press the OK button to test the master valve

and/or pump device.

The device will activate for less than a second

to measure the voltage and current through

the solenoid. This test will return the status of

the device, the device serial number, the

solenoid current, the solenoid voltage, the

two-wire voltage drop, and the version of the

two-wire device. If any zones or programs are running when the test is activated, watering

will pause for 10 minutes.

5. Repeat steps 3 and 4 until you have tested all the master valve and/or pump devices that you

wish to test.

6. When you have finished viewing the test results, press the RUN button to return to the Run