Setting Up Security for the Controller

In the BaseStation 1000 you can set up the following levels of security access:

Admin – Grants access to all controller functions

Programmer – Grants access to all controller functions except the Security function

Operator – Grants access to the Run menu, the Manual Run menu, and the Test menu

After you enable the security and set up the PINs, restart the controller. Users will be prompted to

enter their PIN when they press one of the menu buttons on the controller. If the user does not

have access to the menu, he/she will see the message “Invalid PIN.”

IMPORTANT NOTE!

When a user accesses the controller with a PIN, the controller will maintain

that level of access for 1 hour. When that time is up, anyone who tries to use the controller will be

prompted to enter a PIN.

1. Press the System Setup button. The System

Setup menu displays.

2. Press the  button to highlight the Security

Setup option, and then press the OK button to

select it. The Security Setup screen displays.

3. Press the + button to display a checkmark in

the Enabled field. The PIN fields for the

security levels display.

4. Press the  button to highlight the first digit of the Admin PIN, and then press the + or

button to change the number.

5. Press the  button to move to the next digit, and then press the + or button to change the

number. Repeat this step until you have configured all digits of the PIN.

6. Press the  button to highlight the next PIN, and then repeat steps 5 and 6 until you have

configured all of the PINs.

Clearing the Programming on the Controller

This function will clear or erase all programming information from the controller. We recommend

that you use this function only as directed by Baseline Support.

IMPORTANT NOTE!

Never clear your programming data without having a current backup available

for a restore. Refer to Backing Up the Controller Programming on page 83.

1. Press the System Setup button. The System Setup menu displays.

2. Press the  button to highlight the Clear Programming option, and then press the OK button

to select it. The Clear Programming screen displays.

3. To clear all programming data, press the + button.

Note: To exit this screen without clearing all programming in the controller, press the BACK

button.