Setting a pause condition for a program – Baseline Systems BaseStation 1000 User Manual

Page 56

Advertising
background image

BaseStation 1000 Irrigation Controller Manual

4. Press the + or button to display or remove the checkmark in the Enabled field. When the

checkmark is displayed, the program is active.

5. Press the RUN button to exit Program Setup.

Setting a Pause Condition for a Program

In the BaseStation 1000, you can set up a condition that will cause a running program to pause

when that condition occurs. The following pause conditions are available:

Moisture Pause – If you have a soil moisture sensor installed, you can use this option to have

a program pause when a specified soil moisture sensor limit is reached.

Event Switch Pause – If you have an event switch device installed, you can use this option to

have a program pause when a specified switch condition occurs.

Temperature Pause – If you have an air temperature sensor installed, you can use this option

to have a program pause when a specified temperature is reached.

1. Press the Program Setup button. The Program Setup menu displays.

2. If the program that you want to modify displays in the upper-left corner of the screen,

continue to step 3. Otherwise, press the PRG button until the program that you want to

modify displays in the upper-left corner of the screen.

Note: To move backwards in the list of programs, press and hold the PRG button, and then

press the button repeatedly.

3. Press the  button to highlight the Setup Prg. Pause option, and then press the OK button.

The Setup Prg. Pause screen displays.

Note: If you want the controller to display a message whenever a program is paused, refer to

Enabling Start, Pause, and Stop Messages on page 93.

4. Press the  button to highlight the pause condition that you want to set up for the program,

and then press the OK button. A checkmark displays next to the pause condition that you

selected.

Moisture Pause – If you have a moisture sensor installed, you can use this pause

condition to have a program pause when a specified moisture sensor limit is reached.

When the sensor detects that the condition is no longer present, watering will begin

again.
a. Notice that the serial number for one of your moisture sensors is highlighted in the

Moisture field. If this is the serial number for the sensor installed in the area that

this program will water, no change is required. If you need to assign a different

moisture sensor to the program, press the + or button to select a different serial

number.

b. Press the  button to highlight the Moisture Limit field, and then press the + or

button to change the number in the field. This number represents either the upper

or lower limit.

c.

Press the  button to highlight one of the following pause options, and then press

the OK button: