Setting up a master valve/pump start for a program, Setting up a water source for a program – Baseline Systems BaseStation 1000 User Manual

Page 61

Advertising
background image

BaseStation 1000 Irrigation Controller Manual

Setting Up a Master Valve/Pump Start for a Program

Use this option to associate a master valve or pump start biCoder with a program. Before you

perform this procedure, you must assign a biCoder as a master valve or pump biCoder. Refer to

Searching for and Assigning Master Valve and Pump Start biCoders on page 28.

1. Press the Program Setup button. The Program Setup menu displays.

2. If the program that you want to modify displays in the upper-left corner of the screen,

continue to step 3. Otherwise, press the PRG button until the program that you want to

modify displays in the upper-left corner of the screen.

Note: To move backwards in the list of programs, press and hold the PRG button, and then

press the button repeatedly.

3. Press the  button to highlight the MV/Pump option, and then press the OK button. The

MV/Pump screen displays. The serial numbers of the biCoders that you assigned as master

valve or pump start biCoders display on the left side of the screen.

4. Press the  or  button to move to the serial number of the master valve or pump start

biCoder that you want to associate with this program, and then press the + or button to

select that serial number. A checkmark displays on the right side of the screen.

Setting Up a Water Source for a Program

The BaseStation 1000 can manage 1 complete water source (master valve, flow sensor, and pump

start) and can be upgraded to support up to 3 water sources.

If your controller has been upgraded to support multiple water sources, you can associate a specific

water source with a specific program or associate multiple water sources with one program.

1. Press the Program Setup button. The Program Setup menu displays.

2. If the program that you want to modify displays in the upper-left corner of the screen,

continue to step 3. Otherwise, press the PRG button until the program that you want to

modify displays in the upper-left corner of the screen.

Note: To move backwards in the list of programs, press and hold the PRG button, and then

press the button repeatedly.

3. Press the  button to highlight the Water Source option, and then press the OK button. The

Water Source screen displays. The available water sources are listed. By default, water source

1 (WS-1) is enabled for all programs.

4. Perform one of the following:

If you want to disable WS-1 for a specific program, press the PRG button until the

program that you want to modify displays in the upper-left corner of the screen, and

then press the + or button to remove the checkmark from the WS-1 field.