Testing soil moisture sensors (bisensors) – Baseline Systems BaseStation 1000 User Manual

Page 104

Advertising
background image

BaseStation 1000 Irrigation Controller Manual

Testing Soil Moisture Sensors (biSensors)

When you test a soil moisture sensor (biSensor), the controller verifies the communication

between the controller and the biSensor and returns the following readings:

The status of the biSensor

The biSensor serial number

The current soil moisture percentage value

The soil temperature from the sensor in degrees Fahrenheit

The two-wire voltage drop (a measure of the wire length and quality between the controller

and the biSensor)

Note: Voltage drops greater than 5 volts should be repaired.

The version of the biSensor

1. Press the Test button. The Test menu displays.

2. Press the  or  button to highlight the Test Moisture Sensor option, and then press the OK

button. The Test Moisture Sensor screen displays.

3. Press the  or  button to select the moisture sensor number that you want to test.

4. Press the OK button to test the moisture

sensor.

Note: If any zones or programs are running

when the test is activated, watering will

pause for 10 minutes.

5. Repeat steps 3 and 4 until you have tested all

the moisture sensors that you wish to test.

6. When you have finished viewing the test results, press the RUN button to return to the Run

menu.

Refer to the following table for possible self-test statuses along with causes and suggestions for

resolving the issues.

Self-test

status

Causes/Action

No reply

Two-wire connection to the biSensor is broken – repair the wire and

connections to the biSensor.

Two-wire voltage loss is too high – check other devices in same vicinity

for high two-wire voltage loss – repair high resistance connections

between the controller and devices.

The biSensor is damaged – remove the biSensor and connect it directly

to the controller to test its ability to communicate.

Page 98

Advertising