Viewing fc maintenance information, Maintenance tab field definitions, Figure 8-9 – Dell Emulex Family of Adapters User Manual

Page 126

Advertising
background image

OneCommand™ Manager Application

P010066-01A Rev. A

8. Managing Adapters and Ports

FC/FCoE

126

Note: Some adapters may show additional VPD information such as EC (EC level),

MN (manufacturer ID) and XY data. Data in the YX field is a vendor-specific

hexadecimal dump.

Viewing FC Maintenance Information

Use the Maintenance tab to view firmware information and update adapter firmware.

You can also configure boot from SAN and change WWPN and WWNN information

for the selected adapter port. (Not available in read-only mode.)
To view FC firmware information:
1. Select Host or Fabric view.
2. Select an FC adapter port in the discovery-tree.
3. Select the Maintenance tab.

Figure 8-9 FC Maintenance Tab

Maintenance Tab Field Definitions

Firmware Area

Current Version – The Emulex firmware version number for this model of

adapter.

Initial Load – The firmware version stub responsible for installing SLI code into

its proper slot.

SLI-2 Name – The name of the SLI-2 firmware overlay.

Kernel Version – The version of the firmware responsible for starting the driver.

Operational Name – The name of the operational firmware for the selected

adapter.