Npiv messages (1800–1899) – Dell Emulex Family of Adapters User Manual

Page 684

Advertising
background image

Emulex Drivers for Windows User Manual

P010077-01A Rev. A

4. Troubleshooting

Troubleshooting the FC/FCoE Driver

684

lpfc_mes1401: Invalid tag: ContextIndex: x%x, ulpCommand: x%x

NPIV Messages (1800–1899)

lpfc_mes1800: NPIV FDISC failure VPI: x%x Error x%x Reason x%x

lpfc_mes1801: Memory allocation failure for NPIV port: x%x

lpfc_mes1802: Exceeded the MAX NPIV port: x%x

lpfc_mes1803: Virtual Port: x%x VPI:x%x successfully created.

Description

Firmware has generated an invalid response.

Severity

Error

Log

LOG_LINK_EVENT verbose

Action

Review hardware configuration. Contact Emulex

Technical Support.

Description

Virtual Port fails on a FDISC to the switch with

the error and reason listed.

Severity

Error

Log

LOG_NPIV verbose

Action

Check to ensure the switch supports NPIV.

Description

Fails to allocated the block of memory for the

Virtual Port.

Severity

Error

Log

LOG_NPIV verbose

Action

Check to ensure system has sufficient kernel

memory.

Description

Exceeded the number of Virtual Port allows on

the adapter.

Severity

Error

Log

LOG_NPIV verbose

Action

Reduce the number of Virtual Ports.

Description

Virtual Port ID is successfully created.

Severity

Information

Log

LOG_NPIV verbose

Action

No action needed, informational.

Advertising