4 status messages, 5 tare and zero key functions, 4 status messages 10.5 tare and zero key functions – Rice Lake 880 Performance Series Indicator/Controller Technical/Service Manual User Manual

Page 102: Section 10.4

Advertising
background image

96

880 Technical/Service Manual

10.4 Status Messages

The EDP command

P

can be used to provide status about the indicator.

The

P

EDP command returns whatever is currently shown in the indicator’s primary display area.

PPPPPPP uu

where:

PPPPPPP

is the information shown on the primary display

uu

is the 2-digit units annunciator

If the indicator is in an underrange or overload condition, the weight value is replaced with

&&&&&&

(overload) or

::::::

(underrange).

10.5 TARE and ZERO Key Functions

The function of the front panel TARE and ZERO keys depend on the value specified for the REGULA parameter

in the FEATUR menu, see Figure 3-11 on page 37.
Table 9-4 describes the function of these keys for each of the regulatory modes.

REGULAT

Parameter

Value

Weight on

Scale

Tare in

System

Front Panel TARE Key or KTARE command

(TAREFN – tare function setting)

Front panel ZERO key

or KZERO command

KEYED

PBONLY

BOTH

NTEP

zero or

negative

No

Keyed prompt (1)

No Action

Keyed prompt (1)

Zero

Yes

Keyed prompt (2)

Clear tare

Keyed prompt (2)

Zero

positive

No

Keyed prompt (1)

Tare

Tare

Zero

Yes

Keyed prompt (2)

Tare

Tare

Zero

CANADA

zero or

negative

No

Keyed prompt (1)

No Action

Keyed prompt (1)

Zero

Yes

Keyed prompt (2)

Clear tare

Keyed prompt (2)

Zero

positive

No

No Action

Tare

Tare

Zero

Yes

No Action

No Action

No Action

Zero

OIML

zero or

negative

No

Keyed prompt (1)

No Action

Keyed prompt (1)

Zero

Yes

Keyed prompt (2)

Clear tare

Keyed prompt (2)

Zero and clear Tare (3)

positive

No

Keyed prompt (1)

Tare

Tare

Zero

Yes

Keyed prompt (2)

Tare

Tare

Zero and clear Tare (3)

NONE

zero or

negative

No

Keyed prompt (1)

Tare

Keyed prompt (1)

Zero

Yes

Keyed prompt (2)

Clear tare

Keyed prompt (2)

Zero

positive

No

Keyed prompt (1)

Tare

Tare

Zero

Yes

Keyed prompt (2)

Clear tare

Clear tare

Zero

Note

1.

Entering a Zero tare will CANCEL the entry. Any other value will be accepted as a Keyed Tare.

2.

Entering a Zero tare will CLEAR the current Tare. Any other value will be accepted as a Keyed Tare.

3.

The indicator will Zero and Clear the Tare only is the gross weight if within ZRANGE. No action is taken if the weight is outside
of ZRANGE

Table 10-4. TARE and ZERO Key Functions for REGULA Parameter Settings

Advertising