2 usb memory storage, Usb memory storage – Rice Lake 880 Performance Series Indicator/Controller Technical/Service Manual User Manual

Page 98

Advertising
background image

92

880 Technical/Service Manual

• Key pressed and key released are supported for use by an iRite handler.

• When a USB keyboard is connected - Indicator front panel key operations can be performed on both the 880 keypad and

the USB keyboard.

• These keyboard keys will have no function within the 880:

Scroll Lock
Page Up
Page Down
Insert
Tab
Windows Key
Application Key

9.2.2

USB Memory storage

A USB memory storage device can be used to save the 880 configuration to a file or to load configuration from a

file. Saving or loading configuration is done in the configuration mode using the Load and Save menu items

located in the Ports menu under the Setup Menu. (see Figure 3-16).

Saving Configuration

1. Connect the

USB

memory device to the indicator.

2. Press

MENU

to enter user setup mode.

3. Press or until

PORTS

is displayed.

4. Press ,

COM

is displayed.

5. Press or until

USB

is displayed.

6. Press ,

LOAD

is displayed.

7. Press

SAVE?

is displayed.

8. Press

TARE

to save configuration. The display will say

BUSY

. When save is complete,

SAVED

will be

displayed momentarily, then display will return to

SAVE?

.

Important

If

FAILED

is displayed, the configuration file was not saved. Leave configuration, cycle power, and try

again.

The file is saved as "880_<UID>.txt" (UID is the Unit ID of the indicator). If the file already exists, it is
overwritten without warning.

Loading Configuration

To load a configuration file, use a USB memory device with an appropriate configuration file on it.
The file will either be a "880_<UID>.txt" or "880_<UID>.rev" file (UID matches the Units ID of the Indicator).

Note

If the Unit ID does not match, the indicator will not load the file.

1. Connect the USB memory device to the indicator.

2. Press

MENU

to enter user setup mode.

3. Press or until

PORTS

is displayed.

4. Press ,

COM

is displayed.

5. Press or until USB is displayed.
6. Press ,

LOAD

is displayed.

7. Press ,

ALL?

is displayed.

8. Press or to the desired parameter.

ALL?

to load all parameters

CFG?

to load all except calibration

CAL?

to load just calibration.

Advertising