Sted in table 6-16 ca, Setpoints menu – Rice Lake 880 Performance Series Indicator/Controller Technical/Service Manual User Manual

Page 78

Advertising
background image

72

880 Technical/Service Manual

Setpoints Menu

Note

Table 6-16. Setpoints EDP Commands

Command

Menu

Description

Choices / Range

SP.ACCESS#n

ACCESS

Setpoint access in top level menu (user)

OFF, ON

SP.BANDVAL#n

BNDVAL

Band value

0 - 999999

SP.BRANCH#n

BRANCH

Branch destination

0,1-20

SP.CLRACCM#n

CLRACM

Clear accumulator

OFF, ON

SP.CLRTAR#n

CLRTAR

Clear tare

OFF, ON

SP.DIGOUT#n

DIGOUT

Lists all digital output bits available for the
specified SLOT

NONE, BIT1 – BIT4

SP.END#n

END

Ending setpoint number for TIMER and CONCUR

1- 20

SP.HYSTER#n

HYSTER

Hysteresis

Range:
0 - 65535 (for the COUNTR and
DELAY setpoints)
0 - 999999 (for the GROSS,
NET, and %REL setpoints)

SP.KIND#n

Selection made
directly after
dropping down
from SETPT x

Supported setpoint kinds

OFF, GROSS, NET, -GROSS,
-NET, %REL, PAUSE, DELAY,
WAITSS, COUNTR, AUTJOG,
TIMER, CONCUR

SP.BATSEQ#n

BATSEQ

Specifies whether the setpoint is a batch step

OFF, ON

SP.NAME#n

NAME

Setpoint name string

Alphanumeric, Max Length: 6

SP.PCOUNT#n

PCOUNT

Preact learn interval (number of cycles before it
learns)

Range: 0 - 65535

SP.PREACT#n

PREACT

Preact type

OFF, ON, LEARN

SP.PREADJ#n

PREADJ

Preact adjustment percentage

Range: 0 – 999999

SP.PRESTAB#n

PRESTB

Preact learn stability

Range: 0 - 65535

SP.PREVAL#n

PREVAL

Preact value

Range: 0 - 999999

SP.PSHACCM#n

PSHACM

Push accumulate

OFF, ON, ONQUIET

SP.PSHPRINT#n

PSHPRT

Push print

OFF, ON, WAITSS

SP.PSHTARE#n

PSHTAR

Push tare

OFF, ON

SP.RELNUM#n

RELNUM

Relative setpoint number

1- 20

SP.SENSE#n

SENSE

Digital output sense

NORMAL, INVERT

SP.DSLOT#n

SLOT

Digital output slot

NONE, SLOT0, SLOT1

SP.START#n

START

Starting setpoint number for TIMER and CONCUR 1- 20

SP.TRIP#n

TRIP

Specifies when the setpoint is satisfied when
compared to value

HIGHER, LOWER, INBAND,
OUTBAND

SP.VALUE#n

VALUE

Setpoint value

Range:
0 - 65535 (for the COUNTR
and DELAY setpoints)
0 - 999999 (for the GROSS,
NET, and %REL setpoints)

BATCHNG

BATCHG

Batching enable

OFF, AUTO, MANUAL

Note

For setpoint commands the “n” symbolizes the setpoint number, 1-20.

Different setpoint parameters are available and accepted depending on KIND, TRIP, and PREACT. These
restrictions are listed below by the EDP command name but the same applies to access by menu.

Advertising