6

880 Technical/Service Manual

1.4.6

Preset Tare (Keyed Tare)

Note

Tare mode must be set to keyed or both for the preset tare feature to function.

1. With the scale empty and display showing zero weight, press

TARE

.

2. Display will show (000000); the focused digit will flash.
3. To edit the value:

• Press or to select the digit.
• Press or to increment or decrement the value.

• Press

TARE

to move to the decimal point entry.

• Press or to adjust the decimal point placement.

• Press

TARE

when the value is correct.

4. The display will change to the Net mode and the

PT

LED lights to show the preset tare was entered.

Note

Entering a keyed tare of zero will remove the stored tare value.

1.4.7

Print Ticket

1. Wait for the (

) LED to light.

2. Press

PRINT

to send data to a communications port.

1.4.8

Front Panel Setup

1. Press

MENU

to enter user setup mode. Use user setup to:

• View audit trail information
• Enter setup mode if audit trail is enabled
• View or set time and date
• View or clear the accumulator
• Change setpoint values and enable/disable setpoints
• View the current tare value

1.4.9

Displaying Audit Trail Information

The Audit Trail Configuration and Calibration counters can be viewed through the User Menu.

1. Press

MENU

, AUDIT is displayed.

2. Press to display the Legally Relevant Firmware version.
3. Press to display CALIB.
4. Press to view the Calibration Counter.

5. Press

MENU

to return to CALIB.

6. Press to display CFG.
7. Press to view the Configuration Counter.

8. Press

MENU

to return to CFG.

9. Press

MENU

to return to the weigh mode.

Advertising