1.4.10 Setpoints

Setpoints must be enabled in the setup mode to be accessible in the user setup mode.
To enter the setup mode:

1. Remove the large fillister head screw from the back of the enclosure.
2. Insert a non-conductive tool into the access hole and press the setup switch. Indicator display changes to

show SCALE.

3. Press or until SETPTS is displayed.
4. Press , SP CFG is displayed.
5. Press , press or to desired setpoint number.
6. Press to enter setpoint settings.
7. Select the type by pressing or to desired setting, then press to set the value. For complete list of

options see Section 3.2.13.

8. When all settings have been made, press

MENU

to return to weighing mode.

Note

Setpoints are now accessible from the front panel menu.

Display or Edit Setpoint Value

1. Press

MENU

. AUDIT is displayed.

2. Press or until SETPTS is displayed.
3. Press and the first available setpoint number is displayed.
4. Press or to toggle through each setpoint that is operator accessible.
5. Press , VALUE is displayed.
6. Press again to display or edit the value. To edit the value:

• Press or to increment or decrement the value of the flashing digit.
• Press or to select the digit to edit.

• Press

TARE

to move to the decimal point entry.

• Press or to adjust the decimal point placement.

7. Press

TARE

to accept the displayed value.

8. Repeat the above steps to set PREACT, if enabled

9. When all settings have been made, press

MENU

to return to weighing mode.

Note

Setpoint Value and Preact Value may be accessible from the front panel in weigh mode.

Some indicator configurations may not allow setpoint values to be changed through the front panel or may
require a password to display or change the setpoint value.

Turn Setpoint On or Off

To turn a setpoint off at the front panel:

1. Press

MENU

. AUDIT is displayed.

2. Press or until SETPTS is displayed.
3. Press and the first available setpoint number is displayed.
4. Press or to toggle through each setpoint that is operator accessible.
5. Press , then press or to

ENABLE

.

6. Press , then press or to turn setpoint

ON/OFF

.

7. Press

TARE

to accept the setting.

Advertising