44

880 Technical/Service Manual

COM Menu

Parameter

Choices

Description

TRIGGE

COMAND

Setting Trigger to command allows opration of EDP commands and can print.

STRLFT

Stream Legal for Trade data – data is updated at the configured display update rate.

STRIND

Stream Industrial scale data – data is updated at the configured sample rate.

REMOTE

Configures the port to operate as a serial scale input. See “Menu Structure if
TRIGGE is set to REMOTE” below. (Not available in USBCOM)

Note

When in STRLFT, STRIND and REMOTE, if the COM port is set to TYPE = RS485, the
port will not stream data, and cannot be used in a local/remote application. See
Section 10.6.3.

BAUD

9600
19200
28800
38400
57600
115200
1200
2400
4800

Port baud rate. (Not available in USBCOM)

BITS

8NONE
7EVEN
7ODD

Port data bits and parity. (Not available in USBCOM)

STOP B

1
2

Stop Bits – selects the number of stop bits transmitted and the number of stop bits
expected to be received by the port. (Not available in USBCOM)

TERMIN

CR/LF
CR

Termination – selects the termination character(s) for data sent from the port.

ECHO

ON
OFF

Specifies whether characters received by the port are echoed back to the sending
unit.

RESPNS

ON
OFF

Response – specifies whether the port transmits replies to serial commands

EOLDLY

000000

End of Line Delay - specifies, in 0.1 second intervals, the delay between transmitted
lines of data.

TYPE

232
485

Specifies the protocol for the COM port. (Not available in USBCOM)

ADDRES

0-255

If TYPE is 485, specifies the RS-485 address. (Not available in USBCOM)

PRNMSG

OFF
ON

Print message – displays a message when a print is transmitted on this port.

SFMT

<2><P><W7.>

<U><M><S>

<CR><LF>

Stream format – specifies the stream format used for streaming output of scale data
(TRIGGE=STRLFT or STRIND) or specifies the expected input for a serial scale
(TRIGGE=REMOTE).

Menu Structure if TRIGGE is set to REMOTE

TRIGGE

REMOTE

Configures the port to operate as a serial scale input.

BAUD

9600
19200
28800
38400
57600
115200
1200
2400
4800

Port baud rate.