Configuration

53

PCOUNT

1
1–65535

Preact learn interval. For setpoints with PREACT set to LEARN, specifies the number
of batches after which the preact value is recalculated. The default value, 1,
recalculates the preact value after every batch cycle.

RELNUM

1
1–20

For %REL setpoints, specifies the number of the relative setpoint. The target weight for
this setpoint is the percentage (specified on the VALUE parameter of the %REL
setpoint) of the target value of the relative setpoint

BATSEQ

OFF
ON

Specifies whether the setpoint is used as a batch (ON) or continuous (OFF) setpoint.

CLRACM

OFF
ON

Specify ON to clear the accumulator when the setpoint is satisfied

CLRTAR

OFF
ON

Specify ON to clear the tare when the setpoint is satisfied

PSHACM

OFF
ON
ONQUIE

Specify ON to update the accumulator and perform a print operation when the setpoint
is satisfied (uses the accumulator print format). Specify ONQUIE to update the
accumulator without printing.

PSHPRT

OFF
ON
WAITSS

Specify ON to perform a print operation when the setpoint is satisfied; specify WAITSS
to wait for standstill after setpoint is satisfied before printing.

Note

For AUTJOG setpoints, it will print only once the previous setpoint is
satisfied. Instead of printing the setpoint print format, it will print the
GROSS or NET print format (depends on the type of the previous
setpoint).

PSHTAR

OFF
ON

Specify ON to perform an acquire tare operation when the setpoint is satisfied.

Note

Note

PSHTAR acquires the tare regardless of the value specified for the
REGULA parameter in the FEATUR menu, and regardless of the
stability.

If two or more of the CLRxxx and PSHxxx parameters are set on, the actions specified by those parameters
are performed in the following order when the setpoint is satisfied: 1) clear accumulator; 2) clear tare; 3)
accumulate; 4) print; 5) acquire tare.

ACCESS

ON
OFF

Specifies the access allowed to setpoint parameters shown in the new user menu.

ON: Values can be displayed and changed
OFF: Values can be displayed but not changed

NAME

6ALPHA

A six character alphanumeric name for the setpoint.

SLOT

NONE
SLOT 0
SLOT 1

Lists all available digital I/O slots.

SLOT 0 – onboard DIO

SLOT 1 – Option card (if installed)

Note

A slot will only appear if one or more of its individual bits are
configured as an output.

DIGOUT

BIT 1-4

Lists all digital output bits available for the specified SLOT. This parameter is used to
specify the digital output bit associated with this setpoint. Use the DIG I/O menu to
assign bit function to OUTPUT.

For continuous setpoints, the digital output becomes active (low) when the condition is
met; for batch setpoints, the digital output is active until the setpoint condition is met.

SENSE

NORMAL
INVERT

Specifies whether the state of the digital output associated with this setpoint is inverted
when the setpoint is satisfied.

BRANCH

0
1-20

Specifies the setpoint number to which the batch sequence is to branch if the current
setpoint is not satisfied upon initial evaluation.

The special value zero indicates that no branch is taken.

START

1
1–20

Specifies the starting setpoint number. Do not specify the number of the TIMER or
CONCUR setpoint itself. The TIMER or CONCUR setpoint begins when the starting
setpoint begins.

END

1
1–20

Specifies the ending setpoint number. Do not specify the number of the TIMER or
CONCUR setpoint itself. The TIMER or CONCUR setpoint stops when the ending
setpoint begins.

SETPTS Menu

Parameter

Choices

Description

Table 3-15. Setpoint Menu Parameters