2 panel mount installation – Rice Lake 880 Performance Series Indicator/Controller Technical/Service Manual User Manual

Page 17

Advertising
background image

Installation

11

2.2

Panel Mount Installation

6.0

"

5.3

"

4.0

"

3.0

"

5.0

"

Note

The controller can be mounted to the display DIN rail or mounted remotely up to 250 ft away from display.

Figure 2-1. 880 Panel Mount Dimensions

Use the Din Rail Mount plate as a template (see Figure 2-2) to drill the mounting holes in the panel for the stainless

steel panel mount enclosure. See Figure 2-1 for enclosure dimensions.

1. Mark panel for installation using the DIN rail backer plate and drill the five holes required for mounting.

4.25

"

3.38

"

4.00

"

2.25

"

1.13

"

6.00

"

0.88

"

0.88

"

5/32

" Ш

7/8

" Ш

Use DIN Rail Mount
Plate as a template for
drilling mounting holes
in panel.

Figure 2-2. Pattern for Cutting Holes

2. Install the gasket on the display assembly. It must be seated correctly on display before mounting to ensure

tight seal.

3. Align the display assembly to the front and the DIN rail mounting plate to the back of the panel with the

holes cut in step 1.

4. Secure the display and mounting plate to the panel using the four 6-32 Kep nuts (PN 14621) provided.