11 digital i/o, 12 legal for trade sealing, 11 digital i/o 2.12 legal for trade sealing – Rice Lake 880 Performance Series Indicator/Controller Technical/Service Manual User Manual

Page 28

Advertising
background image

22

880 Technical/Service Manual

2.11 Digital I/O

Digital inputs can be set to provide many indicator functions, including all keypad functions except MENU. Digital

inputs are active (on) with low voltage (0 VDC), inactive (off) at 5 VDC. Use the DIGIO menu to configure the

digital inputs.
Digital outputs are typically used to control relays that drive other equipment. Outputs are designed to sink, rather

than source, switching current. Each output is a normally open collector circuit, capable of sinking 24 mA when

active. Digital outputs are active when low or at 0 VDC, with reference to the 5 VDC supply.
Use the DIO menu to set the function of the DIO pins to OUTPUT, then use the SETPTS menu to configure the

digital outputs.
Table 2-4 shows the pin assignments for connector J2.

Table 2-4. J2 Pin Assignments (Digital I/O)

Connector

Pin

Signal

J2

1

5VDC, 500mA max

2

GND

3

DIO1

4

DIO2

5

DIO3

6

DIO4

2.12 Legal for Trade Sealing

An optional sealing kit (PN 153660) is available for Legal for Trade units.

Load Cell Locking Clip (PN 158402)

6-32 x 1/4 inch
Fillister Head Screw

(PN 158207)

Sealing Wire

Not included

Figure 2-16. Sealing Components

1. Remove the left bottom screw from the backplate as shown in Figure 2-17.
2. Slide the load cell sealing clip over the load cell connector.

Load Cell Locking Clip

Figure 2-17. Remove Existing Screws

3. Secure with one of the fillister head screws provided in the kit.

Advertising