Ports – usbcom menu, Stream tokens menu, Feature menu – Rice Lake 880 Performance Series Indicator/Controller Technical/Service Manual User Manual

Page 76

Advertising
background image

70

880 Technical/Service Manual

Ports – USBCOM Menu

Table 6-9. PORTS – USBCOM EDP Commands

Command

Menu

Description

Choices / Range

EDP.ECHO#2

ECHO

Specifies whether characters received by the port are
echoed back to the sending unit.

OFF, ON

EDP.EOLDLY#2

EOLDLY

Port end-of-line delay

Range: 0 - 255

EDP.PRNMSG#2

PRNMSG

Displays print message

OFF, ON

EDP.RESPONSE#2

RESPNS

Specifies whether the port transmits replies to serial
commands.

OFF, ON

EDP.SFMT#2

SFMT

Stream format

Alphanumeric, max Length: 200

EDP.TERMIN#2

TERMIN

Termination character

CR/LF, CR

EDP.TRIGGER#2

TRIGGE

Selects the operation of the port

COMAND, STRLFT, STRIND

Stream Tokens Menu

Table 6-10. Stream Tokens EDP Commands

Command

Description

Default

Choices / Range

STR.GROSS

String transmitted for the <M> token for gross weight

G

Alphanumeric, Max Length: 8

STR.INVALID

String transmitted for the <S> token when weight is invalid

I

Alphanumeric, Max Length: 2

STR.MOTION

String transmitted for the <S> token when scale is in motion

M

Alphanumeric, Max Length: 2

STR.NEG

Character transmitted for the <P> token when the weight is
negative

-

NONE, SPACE, -

STR.NET

String transmitted for the <M> token for net weight

N

Alphanumeric, Max Length: 8

STR.OK

String transmitted for the <S> token when the scale is ok

“ “

Alphanumeric, Max Length: 2

STR.POS

Character transmitted for the <P> token when the weight is
positive

SPACE

NONE, SPACE, +

STR.PRI

String transmitted for the <U> token for primary units

L

Alphanumeric, Max Length: 8

STR.RANGE

String transmitted for the <S> token when the scale is out of
range

O

Alphanumeric, Max Length: 2

STR.SEC

String transmitted for the <U> token for secondary units

K

Alphanumeric, Max Length: 8

STR.TARE

String transmitted for the <M> token for tare weight

T

Alphanumeric, Max Length: 8

STR.ZERO

String transmitted for the <S> token when the scale is at
center of zero

Z

Alphanumeric, Max Length: 2

Feature Menu

Table 6-11. Feature EDP Commands

Command

Menu

Description

Choices / Range

CONSNUM

CURVAL

Consecutive numbering

0 – 999999

CONSTUP

RESVAL

Consecutive number startup value

0 – 999999

DECFMT

DECFMT

Decimal format

DOT, COMMA

GRAVADJ

LOCALE

Locale - must be enabled for latitude and elevation

OFF, ON

LAT.LOC

LATUDE

Latitude (Locale must be set to ON)

0-90

ELEV.LOC

ELEVAT

Elevation (Locale must be set to ON)

-9999-9999

UID

UID

Unit ID

Alphanumeric, Max Length: 6

ETH.SERVER.TIMEOUT

SERVER | TIMOUT

Inactivity disconnect timeout – connection is
dropped after a specified period (in seconds) of
inactivity. Setting the value to 0 disables the
parameter

Range 0-65535

ETH.SERVER.TRIGGER

SERVER | TRIGGE

Selects the operation of the Server Ethernet
port

COMAND, STRLFT,
STRIND

Table 6-8. PORTS – Ethernet EDP Commands (Continued)

Advertising