When configuration is complete, exit setup mode. Initialize the batch by turning the 3-way switch to

ABORT

, then

unlock the STOP button (the STOP button must be in the OUT position to allow the batch process to run). The

batching switch is now ready to use.

WARNING

If no digital input is assigned to BATRUN, batching proceeds as if BATRUN were always on: the batch will
start when the 3-way switch is turned to RUN, but the STOP mushroom button will not function.

To begin a batch process, turn the 3-way switch to

START

momentarily. If the STOP button is pushed during the

batch process, the process halts and the button locks in the IN position.
The

START

switch is ignored while the STOP button is locked in the IN position. The STOP button must be turned

counterclockwise to unlock it, then released into the OUT position to enable the 3-way switch.
To restart an interrupted batch from the step where it left off, do the following:

1. Unlock STOP button (OUT position).
2. Turn 3-way switch to

START.

To restart an interrupted batch from the first batch step, do the following:

1. Turn 3-way switch to

ABORT.

2. Unlock STOP button (OUT position).
3. Turn 3-way switch to

START.

Note

Use this procedure (or the BATRESET serial command) to initialize the new batch routine following any change
to the setpoint configuration.