Rice Lake 880 Performance Series Indicator/Controller Technical/Service Manual User Manual

Page 46

Advertising
background image

40

880 Technical/Service Manual

REGION Menu, REGULA / INDUST Sub menu

Parameter

Choices

Description

REGULA

NTEP
CANADA
INDUST
NONE
OIML

Regulatory mode – Specifies the regulatory agency having jurisdiction over the scale
site.

Note

The value specified for REGULA affects the function of the front panel
TARE and ZERO keys.

OIML, NTEP, and CANADA modes allow a tare to be acquired at any
weight greater than zero. NONE allows tares to be acquired at any weight
value.

OIML, NTEP, and CANADA modes allow a tare to be cleared only if the
gross weight is at no load. NONE allows tares to be cleared at any weight
value.

NTEP and OIML modes allow a new tare to be acquired even if a tare is
already present. In CANADA mode, the previous tare must be cleared
before a new tare can be acquired.

NONE, NTEP and CANADA modes allow the scale to be zeroed in either
gross or net mode as long as the current weight is within the specified
ZRANGE. In OIML mode, the scale must be in gross mode before it can be
zeroed; pressing the ZERO key in net mode will zero the scale and clear
the tare, if weight is within the specified ZRANGE.

INDUST provides a set of sub-parameters to allow customization of tare,
clear, and print functions in non-legal-for-trade scale installations. See
sub-menu below.

REGWOR

GROSS
BRUTTO

Regulatory Word – Sets the term displayed when weighing in gross mode. Selecting
BRUTTO replaces the Gross annunciator with Brutto.

DECFMT

DOT
COMMA

Decimal Format – Specifies whether decimal numbers are displayed using a period
(DOT) or a comma.

TIME

TFORMT
TSEP
SET

Allows setting of the current time, and the time format and separator character.

DATE

DFORMT
D SEP
SET

Allows setting of the current date, and date format and date separator character.

INDUST sub-menu

SNPSHT

DISPLY
SCALE

Snap Shot uses either the displayed weight or scale weight to determine restrictions.
Allows a method where Industrial mode will take values from the display.

ZTARE

NO
YES

Remove tare on ZERO.

KTARE

NO
YES

Always allow keyed tare.

MTARE

REPLAC
REMOVE
NOTHIN

Multiple tare action.

NTARE

NO
YES

Allow negative or zero tare.

CTARE

NO
YES

Allow CLEAR key to clear tare.

PRTMOT

NO
YES

Allow print while in motion.

PRTPT

NO
YES

Print PT (Preset Tare) for keyed tare entries.

Table 3-9. Region Menu Parameters