6 error commands output, 7 batching control commands, Error commands output – Rice Lake 880 Performance Series Indicator/Controller Technical/Service Manual User Manual

Page 82: Batching control commands, H 6-22

Advertising
background image

Note

76

880 Technical/Service Manual

Digital I/O Control Menu

Table 6-21. Digital I/O Control EDP Commands

Command

Function

DON.b#s

Set digital output on (active) at bit b, slot s

DOFF.b#s

Set digital output off (inactive) at bit b, slot s

Digital inputs and outputs are specified by bit number (b = 1, 2, 3 or 4) and slot number (s = 0 or 1).

The DON/DOFF commands will only control the state of the a slot/bit that is defined as an OUTPUT in the
configuration menu.

6.1.6

ERROR Commands Output

The XE and XEH commands return a representation of any existing error conditions as described Table 10-3 on
page 95.

6.1.7

Batching Control Commands

Table 6-22. Batching Control Commands

Command

Function

BATSTART

Batch start. If the BATRUN digital input is active (low) or not assigned, the BATSTART command can
be used to start the batch program.
If the BATRUN is inactive (high), the BATSART command will reset the batch program to the first
batch step.

BATSTOP

Batch stop. Stops the batch program at the current batch step and turns off all associated digital
outputs.

BATPAUSE

Batch pause. Stops the batch program at the current step. All digital outputs set on by the current
step (except for those set by concur setpoints) are set off. The BATSTR digital input or BATSTART
serial command can be used to restart the batch program at the current step.

BATRESET

Batch reset. Stops the program and resets the batch program to the first batch step. Run the
BATRESET command after making changes to the batch configuration.

Advertising