Introduction

1

About This Manual

This manual is intended for use by service technicians responsible for installing and servicing 880 digital weight

indicators.
This manual applies to indicators using Version 1.01 of the 880 firmware.
Configuration and calibration of the indicator can be accomplished using the indicator front panel keys, the EDP
command set, or Version 3.0 or later of the Revolution

®

configuration utility. See Section 3.1 on page 26 for

information about configuration methods.

Authorized distributors and their employees can view or download this manual from the Rice Lake

Weighing Systems website at

www.ricelake.com

.

An Operator’s Manual is included with the indicator and provides basic operating instructions for users of the 880.

Please leave the Operator’s Manual with the indicator when installation and configuration are complete.

1.0 Introduction

The 880 is a single-channel digital weight indicator housed in a panel mount enclosure. The front panel bezel can

be sealed to a NEMA 4X/IP65 rating. The front panel consists of a 6-button keypad and a 6-digit, 14-segment LED

display.
Features include:

• Drives up to 8 350

or 16 700 load cells

• Supports four and six wire load cell connections
• Four configurable digital inputs or outputs
• Full duplex RS-232 or half duplex RS-485 communications at up to 115200 bps
• Ethernet TCP/IP interface for 10Base-T/100Base-TX network communications
• USB interface for host (type A connection) or device
• Expansion slot for one option card
• Optional DeviceNet

interface for communications network with Allen-Bradley

®

controllers

1

• Optional Ethernet/IP interface for Allen-Bradley PLC and other Ethernet/IP master devices

3

• Optional Profibus

®

DP interface

2

• Optional Modbus TCP interface
• Optional Profinet Interface
• Optional analog output module provides 0–10 VDC, 0-20mA or 4–20 mA tracking of gross or net

weight values

• Optional four channel relay module, dry connect 3A @ 115VAC, 3A @ 30VDC
• Available in 115 VAC and 230 VAC versions