2 setup menu, Setup menu, Figure 3-7 – Rice Lake 880 Performance Series Indicator/Controller Technical/Service Manual User Manual

Page 36

Advertising
background image

30

880 Technical/Service Manual

3.2.2

Setup Menu

SCALE

FEATUR

PORTS

PFORMT

SETPTS

DIGIO

ALGOUT

VERS

AUDIT

TARE

SETPTS

T & D

ACCUM

SETUP

Figure 3-7. Setup Menu Structure

SETUP Menu

Parameter

Choices

Description

SCALE

GRADS
SPLIT
FORMAT
ZTRKBN
ZRANGE
MOTBAN
OVRLOA
SSTIME
DSPRAT
SMPRAT
DFSENS
DFTHRH
TAREFN
PWRUPM
ACCUM
THRESH
CALIB

Configure and calibrate scale.

See Figure 3-8 for Scale menu structure.

See Figure 3-9 for Format menu structure.

See Figure 3-10 for Calibration menu structure.

FEATUR

REGION
UID
CONSC#
PASSWD
KEYLCK
LOCALE
LATUDE
ELEVAT

Feature – set miscellaneous system attributes.

See Figure 3-11 for Feature menu structure.

See Figure 3-12 for Region and Regulatory menu structure.

PORTS

COM
USBCOM
ETHNET
USB
FLDBUS

Configure Communication Ports.

See Figure 3-13 for PORTS menu structure.

See Figure 3-14 for COM menu structure.

See Figure 3-15 for ETHNET menu

PFORMT

GFMT
NFMT
ACCFMT
SPFMT
HDRFMT

Set print format used for header, gross, net, and setpoint ticket formats.

See Figure 3-17 for Print Format menu structure.

See Section 7.0 for detailed information on print formatting.

SETPTS

SP CFG
BATCHG

Configure setpoints and batching mode.

See Figure 3-18 for Setpoint menu structure.

See Figure 3-19 for Gross, Net and %Rel Setpoints.

See Figure 3-20 for Pause, Delay, WaitSS, Counter and Autojog Functions.

See Figure 3-21 for Timer and Concur Functions.

DIGIO

SLOT 0

Assigns digital input/output functions. See Figure 3-22 for Digital I/O menu structure.

Table 3-4. Setup Menu Parameters