Rice Lake 880 Performance Series Indicator/Controller Technical/Service Manual User Manual

Page 39

Advertising
background image

Configuration

33

TAREFN

BOTH
NOTARE
PBTARE
KEYED

Tare function – Enables or disables push-button and keyed tare.

BOTH – Both push-button and keyed tares are enabled
NOTARE – No tare allowed (gross mode only)
PBTARE – Push-button tares enabled
KEYED – Keyed tare enabled

PWRUPM

GO
DELAY

Power up mode.

GO - In GO mode, the indicator goes into operation immediately after a brief power up
display test.
DELAY - the indicator performs a power up display test, then enters a 30-second warm up
period. If no motion is detected during the warm up period, the indicator becomes
operational when the warm up period ends; if motion is detected, the delay timer is reset
and the warm up period repeated.

ACCUM

OFF
ON

Accumulator – specifies if the scale accumulator is enabled or disabled. If enabled, accumulation
occurs every time a print operation is performed, while the weight is above the accumulator reset
threshold, as long as the weight returns to a value lower than the threshold between print
operations.

THRESH

0-999999

Accumulator Reset Theshold – when the weight falls below the value set, the accumulator is
rearmed.

CALIBR

WZERO
WVAL
WSPAN
WLIN
REZERO
LAST
TEMP

Calibration – See Figure 3-10 for descriptions, and see Section 4.0 for calibration procedures.

SCALE Menu

Parameter

Choices

Description

Table 3-5. Scale Menu Parameters (Continued)