69bdisplaying average sample weight, 69b displaying average sample weight, Displaying average sample weight – Rice Lake TS Series, Rice Lake Weighing Systems - Operation Manual User Manual

Page 31

Advertising
background image

RL-TS Series Operation Manual 27

7

Put additional samples.

Put additional samples. The number of additional samples is

up to three times the set number of samples.

For example, if “10 Pcs” is set, add 30 or less samples.

A blip sound reports you that added samples have been

measured.
Repeating this sample addition step can improve the

resolution of parts counting.

8

Finish sampling.

Press the [Function] key.
The average sample weight is saved and the balance returns

to measurement mode.



9

Place samples to count them.

Pressing the [Function] key toggles the display between

number of samples, average sample weight, and total weight.

69B

Displaying average sample weight

When weighing in parts counting mode, pressing the [Function] key can display average sample weight.
Pressing the [Function] key toggles the display between number of samples, average sample weight, and
total weight.

参 考

- The “Sub” display indicates that you added more than three times as many samples as

the set number. Decrease the number of additional samples. Starting from a small
number of samples, gradually increase the number of samples to increase counting
accuracy.

- The “Add” display indicates that the number of added samples is too small. Increase

the number of additional samples.

- Even when these indications are displayed, sampling is possible. In this case, however,

counting accuracy is low.

- [L - Err] is displayed to indicate that the average sample weight is smaller than the

weighable unit weight (Refer to “Appendix 4: Specifications” (P.

X

94

X

)).

Ref

Advertising