45bsetting a reference weight by entering a value, 45b setting a reference weight by entering a value, Setting a reference weight by entering a value – Rice Lake TS Series, Rice Lake Weighing Systems - Operation Manual User Manual

Page 33

Advertising
background image

RL-TS Series Operation Manual 29

45B

Setting a reference weight by entering a value

1

Set to the function setting mode.

(Refer to “Section 2-5: Function Setting Basics
(P.

X

22

X

).)

Press and hold the [Function] key. After “Func” is

displayed, release the finger.

2

Select “Percentage Weighing.”

Press the [Zero/Tare] key several times to select “1.SEt

3

.”



3

Save the weighing mode.

Press the [Target] key.
The “percent weighing” mode is set, displaying “%.”


4

Start setting the reference weight.

<Press and hold>

Press and hold the [Function] key. After “P SEt” is

displayed, release the finger.
The previously-saved reference sample weight blinks.

5

Enter a reference weight.

Set the reference value with the following steps:

1. Press the [Zero/Tare] key.

The digit furthest to the right side of the value
blinks..

2. Select a number by pressing the [Zero/Tare] key.

Pressing the key toggles the number between 0 and
9, and decimal point.

3. Pressing the [Function] key selects the number and

the next digit blinks.


Set the reference weight by repeating steps 2 and 3.

Pressing the [Print] key can cancel the setting.

6

Save the value.

Press the [Target] key to save the reference weight.




Advertising