16b3.4 obtaining weight multiplied by coefficient, 16b 3.4, Obtaining weight multiplied by coefficient – Rice Lake TS Series, Rice Lake Weighing Systems - Operation Manual User Manual

Page 35: 4 obtaining weight multiplied by coefficient

Advertising
background image

RL-TS Series Operation Manual 31

16B

3.4 Obtaining Weight Multiplied by Coefficient

Measured weight is multiplied by a set coefficient, and the result can be displayed.

For example, if “2.35” is set for the coefficient, and the weight of the sample is “2,000 g,” the given readout
is “4,700.”

(Example) Sample (2,000 g) × Coefficient (2.35) → Readout (4700)

1

Set to the function setting mode.

(Refer to “Section 2-5: Function Setting Basics
(P.

X

22

X

).)

Press and hold the [Function] key. After “Func” is

displayed, release the finger.

2

Select “Unit Converting.”

Press the [Zero/Tare] key several times to select “1. SEt

4

.”

3

Save the weighing mode.

Press the [Target] key.
The “unit converting” mode is set, displaying “#.”

4

Set to the coefficient setting mode.

<Press and hold>

Press and hold the [Function] key. After “C. SEt” is

displayed, release the finger.
The previously-saved coefficient is displayed.


5

Enter a coefficient.

Set a coefficient with the following steps:

1. Press the [Zero/Tare] key.

The digit furthest to the right side of the value

blinks.

2. Select a number by pressing the [Zero/Tare] key.

Pressing the key toggles the number between 0 and

9, and decimal point.

3. Pressing the [Function] key selects the number and

the next digit blinks.

Set the coefficient by repeating steps 2 and 3.
Pressing the [Print] key can cancel the setting.

Advertising