51baddition function setting, 51b addition function setting, 7 adding multiple measurements – Rice Lake TS Series, Rice Lake Weighing Systems - Operation Manual User Manual

Page 44: Reference, Addition function setting

Advertising
background image

40 RL-TS Series Operation Manual

3.7 Adding Multiple Measurements

Multiple samples are weighed consecutively and the sum is displayed.
The weighing method can be selected from reloading samples (cumulate function) or without replacing
samples (net addition function).

The addition function can be used in the following weighing modes: weighing machine,

parts counting, percentage weighing, and unit converting.

51B

Addition function setting

1

Set to the function setting mode.
(Refer to “Section 2-5: Function Setting

Basics (P. 22).)

Press and hold the [Function] key. After “Func” is

displayed, release the finger.

2

Select Addition Function.

Press the [Function] key several times to select

“2.SEL.”
Press the [Zero/Tare] key to select “2.SEL 1.”

When using both the cumulate and limit functions

together, select “2.SEt 3.”
For more information on the limit function, refer to

“Section 3-8: Judging “Above” and “Below”” (P.

X

42

X

).

3

Select cumulate or net addition.

Press the [Function] key. After “2.C.A d.” is displayed,

press the [Zero/Tare] key to set the value.
1: Cumulate function
2: Net addition function

4

Finish setting.

Press the [Target] key.
The addition function is set.

Reference

Reference

Advertising