28 RL-TS Series Operation Manual

15B

3.3 Measuring Percentage

With respect to the reference sample weight, the weight of a sample is shown in percentage.
A reference sample weight can be set by weighing an actual sample (setting a reference weight by weighing

an actual sample) or entering a value (setting a reference weight by entering a value).

44B

Setting a reference weight by weighing an actual sample

1

Set to the function setting mode.

(Refer to “Section 2-5: Function Setting Basics
(P.

X

22

X

).)

Press and hold the [Function] key. After “” is displayed,

release the finger.

2

Select “Percentage Weighing.”

Press the [Zero/Tare] key several times to select “1.SEt 3.”

3

Save the weighing mode.

Press the [Target] key.
The “percent weighing” mode is set, displaying “%.”

4

Start measuring the reference weight.

<Press and hold>

Press and hold the [Function] key. After “ ” is displayed,

release the finger.
The previously-saved reference sample weight blinks.

5

Save the reference weight.

Put the reference sample on the balance and then press the

[Function] key.
The reference weight is saved.


6

Weigh.

The display indicates the percentage of the sample with respect

to the reference sample weight.
Pressing the [Function] key toggles the display between

percentage weight and total weight.