Rice Lake TS Series, Rice Lake Weighing Systems - Operation Manual User Manual
Page 76
72 RL-TS Series Operation Manual
* -
If headed with no data, the numeric value is headed by 0 (30H) by factory default setting. Using the
function setting, it can be headed by “SP” (20H).
-When expression units are changed or switched to display of parts counting, percentage weighing, or
unit converting, the decimal place is changed (Refer to “ Sample communication formats” (P. 70)).
[U1, U2] (two characters)
Indicates the unit used to show numeric data.
U1
U2
Code
Meaning
Balance indicator
(SP)
G
20H
47H
gram
g
K
G
4BH
47H
Kilogram
kg
C
T
43H
54H
carat
CT
O
Z
4FH
5AH
ounce
L
B
4CH
42H
pound
O
T
4FH
54H
troy ounce
D
W
44H
57H
pennyweight
G
R
4BH
52H
Grain
Bottom right
grain
T
L
54H
4CH
tael (Hong Kong)
T
L
54H
4CH
tael (Singapore, Malaysia)
Top right
T
L
54H
4CH
tael (Taiwan)
Middle right
M
O
4DH
4FH
momme
mom
t
o
74H
6FH
tola
P
C
50H
43H
Pieces
Pcs
(SP)
%
20H
25H
Percentage
%
(SP)
#
20H
23H
Computation results, numbers, etc. #
[S1] (one character)
Indicates the judgment result when the limit function is used.
S1
Code
Description
Remarks
L
4CH
Below (LO)
1- or 2-point scale
G
47H
Appropriate (OK)
H
48H
Above (HI)
T
54H
Cumulative value
Data type
U
55H
Unit weight
(SP)
20H
No judgment result or no data type specified
d
64H
Gross