72 RL-TS Series Operation Manual

* -

If headed with no data, the numeric value is headed by 0 (30H) by factory default setting. Using the

function setting, it can be headed by “SP” (20H).

-When expression units are changed or switched to display of parts counting, percentage weighing, or

unit converting, the decimal place is changed (Refer to “ Sample communication formats” (P. 70)).

[U1, U2] (two characters)

Indicates the unit used to show numeric data.

U1

U2

Code

Meaning

Balance indicator

(SP)

G

20H

47H

gram

g

K

G

4BH

47H

Kilogram

kg

C

T

43H

54H

carat

CT

O

Z

4FH

5AH

ounce

L

B

4CH

42H

pound

O

T

4FH

54H

troy ounce

D

W

44H

57H

pennyweight

G

R

4BH

52H

Grain

Bottom right

grain

T

L

54H

4CH

tael (Hong Kong)

T

L

54H

4CH

tael (Singapore, Malaysia)

Top right

T

L

54H

4CH

tael (Taiwan)

Middle right

M

O

4DH

4FH

momme

mom

t

o

74H

6FH

tola

P

C

50H

43H

Pieces

Pcs

(SP)

%

20H

25H

Percentage

%

(SP)

#

20H

23H

Computation results, numbers, etc. #

[S1] (one character)

Indicates the judgment result when the limit function is used.

S1

Code

Description

Remarks

L

4CH

Below (LO)

1- or 2-point scale

G

47H

Appropriate (OK)

H

48H

Above (HI)

T

54H

Cumulative value

Data type

U

55H

Unit weight

(SP)

20H

No judgment result or no data type specified

d

64H

Gross

Advertising