Appendix 1 function setting list, Rl-ts series operation manual 87, Additional – Rice Lake TS Series, Rice Lake Weighing Systems - Operation Manual User Manual

Page 91

Advertising
background image

RL-TS Series Operation Manual 87

Appendix 1

Function Setting List

Additional

Animal weighing selected

Cumulate

function” or

“Cumulate function

+ Limit function”

selected

(Continued on next page.)

(Select output data)

(Auto output)

(Auto tare setting)

(Output a hold value)

(Weight variation range of hold)

Animal-only response speed

Additional function disabled

Cumulate function selected
Limit function selected
Cumulate function + Limit function

(Condition)

(Range to cover)

(Point scale)

(Judge by)

(Buzzer when LO is

judged)

(Buzzer when OK is

judged)

(Buzzer when HI is

judged)

(How to indicate

results)

(Addition operation)

Water 
Not water
Only a specific gravity value 
Specific gravity, weight, actual water temperature or

medium density
Output disabled 
Auto output once after a specific gravity measurement

OFF
ON 

OFF 
ON (Auto output once after weight hold)

20 times the minimum readability
50 times the minimum readability 
100 times the minimum readability
Fast
Middle 
Slow

Always judge (even when the balance is unstable) 

Judge only when the balance is stable (not judge when the balance is

unstable)

Detect when the limit is exceeded by more than five divisions
Detect both when the limit is exceeded and when it is not reached

1-point scale (OK/LO are judged)
Upper and lower limits (HI/OK/LO are judged) 

Judge by absolute value 
Judge by deviation value

Buzzer not beeped for rank LO 
Buzzer beeped for rank LO

Buzzer not beeped for rank OK 
Buzzer beeped for rank OK

Buzzer not beeped for rank HI 
Buzzer beeped for rank HIK

HI/OK/LO 
2-point bar graph (Available only for 2-point scale)

Cumulate 
Net addition

Limit function” or

“Cumulate function

+ Limit function”

selected

Auto-zero

Stability judgment

Response speed

Interface

When 1, 2, or 3 is

selected in “”

When 3 is selected in

“”

When 1, 2, or 3 is

selected in “”

When 2, or 3 is

selected in “”

Disabled
Enabled 

Wide (Mild)

Narrow (Strict)

Measurement by consecutive weighings
Fast

Slow

Stop input/output
Numeric 6-digit format 
Numeric 7-digit format
Extended numeric 7-digit format

(Output control)

(Baud rate)

(Parity)

(Data length)

(Stop bit)

(Unused high order

digits)

(Response

commands)

* Select “1” or ”2” if using a supported printer.

Stop output.
Output continuously at all times.
Output continuously if stable (stop output if unstable).
Output once when the [Print] key is pressed (whether the balance is

stable or unstable).

Output once when the balance is stable.

Output when a sample is lifted to cause the display to indicate a value below 0, and

then another sample is placed to make the balance stable.

Output once when the balance is stable.

Stop output when unstable. Output once when the balance is stabilized again even if it

is not reloaded (the output includes zero).

Output once when the balance is stable.

Output continuously when unstable. Output is stopped after a single output when the

balance is stable even if it is not reloaded.

Output once when the [Print] key is pressed if the balance is stable 

1200 bps 
2400 bps
4800 bps
9600 bps
19200 bps

None 
Odd
Even

7 bit
8 bit 

1 bit
2 bit 

Embed 0 (30H) 
Embed space (20H)

A00, Exx 
ACK, NAK

A star () denotes an initial value.

A star () denotes an initial value.

A star () denotes an initial value.

(Continued on next page.)

Span

adjustment/test

Bar graph

Auto power off

Auto backlight off

Unit setting

Minimum readability

Unit setting

Minimum readability

i

ISO/GLP/GMP compliance

(Unit A)

(Unit A)

(Unit B)

(Unit B)

When 1 is selected in 


CAL operation disabled
Span adjustment with external weight 
Span test with external weight

Not displayed
Displayed 

Disable (for continuous use) 
Enable (The power is turned off five minutes later.)

* Enabled only when the balance is powered

by batteries

Disable (for continuous use) 
Enable (The backlight goes off if the balance is not used for about three minutes.)

g (gram) 
kg (kilogram)
ct (carat)
oz (ounce)
lb (pound)

ozt (troy ounce)
dwt (penny weight)
GN (grain)
tl (tael (Hong Kong))
tl  Upper right (tael (Singapore, Malaysia))
tl  Right middle (tael (Taiwan))

mom (momme)

to (tola)

None 
g (gram)

kg (kilogram)
ct (carat)
oz (ounce)
lb (pound)
ozt (troy ounce)
dwt (penny weight)

GN (grain)
tl (tael (Hong Kong))
tl  Upper right (tael (Singapore, Malaysia))
tl  Right middle (tael (Taiwan))

mom (momme)

to (tola)

Fine 

Rough

Fine 

Rough

Disabled 

Enabled

(Outputting calibration

results)

(Measurement data in

compliance with GLP)

(Language for

printing)

Disabled
Enabled 

Disabled 
Enabled

English 
Japanese (katakana)

Set tare range

Store tare

Buzzer control

Backlight control

“0” is displayed immediately after the key is pressed.
Reset the display to “0” when the balance is stabilized. 

Disabled 
Enabled

Off
On (Beeps when a value is confirmed, wrong operation is made, etc.)
Beeps when the key is pressed in addition to the beeping situations in 1. 

(Buzzer tone)

* When “1” or ”2” is selected

in “ ”

Low
Middle 
High

Off
On
On when the balance is powered by the AC adapter.
Off when powered by batteries. 

Advertising