23b 5-1, Using two expression units by switching, Them – Rice Lake TS Series, Rice Lake Weighing Systems - Operation Manual User Manual
Page 59: 1 using two expression units by switching them, Reference
RL-TS Series Operation Manual 55
23B
5-1 Using Two Expression Units by Switching Them
You can set two units (unit A and unit B) and switch between the units.
Unit B can be used only in weighing machine mode. Unit A can be used in all measurement
modes.
For more information on selectable units, refer to “Appendix 1: Function Setting List” (P.
1
Set to the function setting mode.
(Refer to “Section 2-5: Function Setting
).)
Press and hold the [Function] key. After
“Func” is displayed, release the finger.
2
Set unit A.
Press the [Function] key several times to select
“bl.uR.”
Select unit from the following numbers by
pressing the [Zero/Tare] key.
1: g/2: kg/4: ct (carat), etc.
When setting only the unit A, press the [Target]
key in this step to save the setting.
3
Set unit B.
Press the [Function] key several times to select
“b3.ub.”
Select unit from the following numbers by
pressing the [Zero/Tare] key.
1: g/2: kg/4: ct (carat), etc.
Unit B can be used only in weighing machine
mode.
4
Save the setting.
Press the [Target] key.
The balance goes back to normal display.
5
How to switch between unit A and unit B
Pressing the [Function] key during measurement
switches between unit A and unit B.
Reference
Reference