6. On the Advanced Options tab, on the DQS IN page, specify the parameters as

shown in

Table 2–6

. These parameters configure the DQS input path of the

ALTDQ_DQS instance.

Table 2–5. Parameter Settings

Parameter

Value

RLDRAMII Mode

NONE

Number of bidirectional DQ

0

Number of input DQ

8

Number of output DQ

0

Number of stages in dqs_delay_chain

3

DQS input frequency

150 MHz

Use half-rate components

Turned off.

The design uses full-rate
memory components, so
you do not select this
option.

Use Dynamic OCT

Turned off.

Dynamic OCT is not used for
input paths.

Add memory interface specific fitter grouping assignments

Turned on.

Table 2–6. Advance Options (DQS IN)

Parameter

Sub-options

Value

Enable DQS Input Path

Turned on.

Enable dqs_delay_chain

Selected.

Advanced delay chain options

Select dynamically using
configuration registers

Turned off.

DQS delay chain
‘delayctrlin’ port source

DLL

The DQS delay-chain settings
is based on the DLL.

DQS Delay Buffer Mode

Low

Use the same mode selected
in the DLL settings.

DQS Phase Shift

9000..

Specify a 90° DQS phase shift.
The phase-shift value must
inter-relate with the selected
dqs_delay_chain stage.

Enable DQS offset control

Turned off.

Disable DQS delay fine-tuning
using offset feature.

Enable DQS delay chain
latches

Turned off.

Advertising