Dqs oe path megafunction ports, Dqs oe path megafunction ports –36 – Altera ALTDLL User Manual

Page 72

Advertising
background image

Chapter 4: Functional Description

4–36

ALTDQ_DQS Megafunction Ports

© February 2012

Altera Corporation

ALTDLL and ALTDQ_DQS Megafunctions User Guide

DQS OE Path Megafunction Ports

Table 4–13

summarizes all the ports on the megafunction that configure the DQS OE

path.

Table 4–13. Megafunction Ports to Configure DQS OE Path

Port Name

Type

Optional/
Required

Default

Description

dqs_areset

Input

Optional

GND

This port is connected to the

DQS_OE_FF:clrn

,

DQS_OE_DDIO_OE:areset

, and

DQS_OE_HR_DDIO_OUT:areset

ports that is

used to asynchronously reset all registers in those
blocks.

dqs_hr_oe_in[1..0]

Input

Optional

GND

This 2-bit port is connected to the

DQS_OE_HR_DDIO_OUT:datainhi

/

datainlo

port that is used as the output enable for

the half-rate registers in that block.

dqs_hr_output_reg_clk

Input

Optional

GND

This port is connected to the

DQS_OE_HR_DDIO_OUT:clkhi

/

clklo

/

muxsel

ports that is used to clock the half-rate

registers in those blocks.

dqs_oe_in

Input

Optional

GND

This port feeds the

DQS_OE_FF:d

,

DQS_OE_DDIO_OE:oe

,

DQS_OE_DELAY_CHAIN1:datain

,

DQS_OE_DELAY_CHAIN2:datain

, or

dqs_oe_out

port. For information about how to

enable these blocks, refer to

“Parameter Settings” on

page 3–1

.

dqs_oe_out

Output

Optional

This port receives the output signal from the

DQS_OE_DELAY_CHAIN2:dataout

,

DQS_OE_DELAY_CHAIN1:dataout

,

DQS_OE_FF:q

,

DQS_OE_DDIO_OE:dataout

,

or

dqs_oe_in

port. For information about how to

enable these blocks, refer to

“Parameter Settings” on

page 3–1

.

dqs_output_reg_clk

Input

Optional

GND

This port is connected to the

DQS_OE_FF:clk

and

the

DQS_OE_DDIO_OE:clk

ports that is used to

clock the registers in those blocks.

dqs_output_reg_clkena

Input

Optional

V

CC

This port is connected to the

DQS_OE_FF:ena

and

the

DQS_OE_DDIO_OE:ena

ports that is used as

output enable for the registers in those block.

dqs_sreset

Input

Optional

GND

This port is connected to the

DQS_OE_FF:sclr

and

DQS_OE_DDIO_OE:sreset

ports that is used

to synchronously reset all registers in those blocks.