potentially errored packet, and the application can rely on the fact that if

irx_err

is not asserted and

irx_eopbits

has a value other than 4'b0001, the packet is not errored.

For CRC24 errors, you should use the

crc24_err

status signal, rather than relying on the

irx_err

signal,

in the following situations:
• If you monitor the link when only Idle control words are being received (no data is flowing), you

should monitor the real time status signal

crc24_err

.

• If you maintain a count of CRC24 errors, you should monitor the number of times that the real time

status signal

crc24_err

is asserted.

50G Interlaken IP Core Receiver Side Example With Errors and In-Band Calendar Bits

Figure 4-9: 50G Interlaken IP Core Receiver Side Example With irx_err Errors

This example illustrates the expected behavior of the 50G Interlaken IP core application interface receive

signals during a packet transfer with CRC or other errors. In the example, the errored packet transfer is

followed by two idle cycles and a non-errored packet transfer.

rx_usr_clk

irx_sop

irx_chan

irx_sob

irx_eob

irx_dout_words

irx_num_valid

irx_eopbits

irx_calendar

irx_err

Cycle 1 Cycle 2 Cycle 3 Cycle 4 Cycle 5 Cycle 6 Cycle 7 Cycle 8 Cycle 9

8’h2

8’h3

d1

d2

d3

d4

d5

d6

3’b100 3’b100

3’b100

3’b011 3’b000

3’b100 3’b010

4’b0000

4’b0000

4’b1011

4’b1011

64’hffff_ffff_ffff_ffff

///////////64’h1111_2222_3333_4444

This figure illustrates the attempted transfer of a 83-byte packet on the RX user data transfer interface to

channel 2, after the 50G Interlaken IP Core receives the packet on the Interlaken link and detects

corruption. Following the errored packet, the IP core transfers an uncorrupted packet to channel 3.
In cycle 1, the 50G Interlaken IP Core asserts

irx_sop

when data is ready on

irx_dout_words

. When the

50G Interlaken IP Core asserts

irx_sop

, it also asserts the correct value on

irx_chan

to tell the applica‐

tion the data channel destination of the data. In this example, the value 2 on

irx_chan

tells the application

that the data should be sent to channel number 2.
During the SOP cycle (labeled with data value d1) and the cycle that follows the SOP cycle (labeled with

data value d2), the 50G Interlaken IP Core holds the value of

irx_num_valid[2:0]

at 3'b100. In the

UG-01140

2015.05.04

50G Interlaken IP Core Receiver Side Example With Errors and In-Band Calendar Bits

4-17

Functional Description

Altera Corporation

Send Feedback