Specification, Revision 1.2. The TX Out-of-Band Flow Control Block Signals for Application Use table

describes the signals on the application side of the TX out-of-band flow control block.

Table 10-2: TX Out-of-Band Flow Control Interface Signals

Signal Name

Direction

Width

(Bits)

Description

fc_clk

Output

1

Output reference clock to an upstream out-of-band RX block.

Clocks the

fc_data

and

fc_sync

signals. You must connect

this signal to a device pin.

fc_data

Output

1

Output serial data pin to an upstream out-of-band RX block.

You must connect this signal to a device pin.

fc_sync

Output

1

Output sync control pin to an upstream out-of-band RX block.

You must connect this signal to a device pin.

Table 10-3: TX Out-of-Band Flow Control Block Signals for Application Use

Signal Name

Direction

Width

(Bits)

Description

double_fc_clk

Input

1

Reference clock for generating the flow control output clock

fc_clk

. The frequency of the

double_fc_clk

clock must be

double the intended frequency of the TX

fc_clk

output clock.

double_fc_

arst

Input

1

Asynchronous reset for the out-of-band TX block.

ena_status

Input

1

Enable transmission of the lane status and link status to the

downstream out-of-band RX block. If this signal is asserted,

the lane and link status information is transmitted on

fc_data

.

If this signal is not asserted, only the calendar information is

transmitted on

fc_data

.

lane_status

Input

Number

of Lanes

Lane status to be transmitted to a downstream out-of-band RX

block if

ena_status

is asserted. Width is the number of lanes.

link_status

Input

1

Link status to be transmitted to a downstream out-of-band RX

block if

ena_status

is asserted.

calendar

Input

16

Calendar status to be transmitted to a downstream out-of-band

RX block.

Related Information

Interlaken Protocol Specification, Revision 1.2