Out-of-band flow control block clocks, Tx out‑of‑band flow control signals, Out-of-band flow control block clocks -2 – Altera 50G Interlaken MegaCore Function User Manual

Page 85: Tx out-of-band flow control signals -2, Tx out-of-band flow control signals

Advertising
background image

Related Information

Interlaken Protocol Specification, Revision 1.2

Out-of-Band Flow Control Block Clocks

Table 10-1: 50G Interlaken MegaCore Function Out-of-Band Flow Control Block Clocks

Clock Name

Interface

Direction Recommende

d Frequency

(MHz)

Description

RX

fc_clk

RX Out-of-

band

Input

100

Clocks the incoming out-of-band flow control

interface signals described in the Interlaken

specification. This clock is received from an

upstream TX out-of-band flow control block

associated with the Interlaken link partner. The

recommended frequency for the RX

fc_clk

clock

is 100 MHz, which is the maximum frequency

allowed by the Interlaken specification.

TX

fc_clk

TX Out-of-

band

Output

100

Clocks the outgoing out-of-band flow control

interface signals described in the Interlaken

specification. This clock is generated by the

out-of-band flow control block and sent to a

downstream RX out-of-band flow control block

associated with the Interlaken link partner. The

frequency of this clock must be half the frequency

of the

double_fc_clk

clock. The recommended

frequency for the TX

fc_clk

clock is 100 MHz,

which is the maximum frequency allowed by the

Interlaken specification.

sys_clk

RX

Application

Input

200

Clocks the outgoing calendar and status informa‐

tion on the application side of the block. The

frequency of this clock must be at least double the

frequency of the RX input clock

fc_clk

.

Therefore, the recommended frequency for the

sys_clk

clock is 200 MHz.

double_

fc_clk

TX

Application

Input

200

Clocks the incoming calendar and status informa‐

tion on the application side of the block. The

frequency of this clock must be double the

frequency of the TX output clock

fc_clk

.

Therefore, the recommended frequency for the

double_fc_clk

clock is 200 MHz.

TX Out‑of‑Band Flow Control Signals

The transmit out-of-band flow control interface receives calendar and status information, and transmits

flow-control clock, data, and sync signals. The TX Out-of-Band Flow Control Interface Signals table

describes the transmit out-of-band flow control interface signals specified in the Interlaken Protocol

10-2

Out-of-Band Flow Control Block Clocks

UG-01140

2015.05.04

Altera Corporation

Out-of-Band Flow Control in the 50G Interlaken MegaCore Function

Send Feedback

Advertising