System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)

50

The shelf management resource contains the following two RDRs:

Domain management control
Read-only HPI control which allows the application to obtain the IP address, port, domain
name and other connection parameters of a particular shelf

Connection status sensor
Contains information about the current status of the connection to a shelf

The definitions of both HPI controls are given in the following.

4.4.3.2.1 Domain Management Control

This HPI control is only readable. It has the same structure and definition as the HPI controls
defined in

Table "Domain Management Control" on page 48

,

Table "Domain Management

Control State" on page 48

and

Table "Domain Management Control RDR" on page 48

.

4.4.3.2.2 Connection State Sensor

This HPI sensor represents the status of the connection to a shelf. When the connection is
interrupted, an HPI event of type SAHPI_ES_OFF_LINE is generated. When the connection is
reestablished, an HPI event of type SAHPI_ES_ON_LINE is generated. An application can access
a shelf only when the state of this sensor is SAHPI_ES_ON_LINE. The definition of this sensor is
given in the following tables.

Table 4-7 Connection State RDR

SaHpiRdrT

Value

RecordId

Assigned by HPI

RdrType

SAHPI_SENSOR_RDR

Entity

The same entity as domain management resource

RdrTypeUnion

MOTHPI_SENSOR_NAME_DOMAIN_CONNECTION

Table 4-8 Domain Connection Sensor

SaHpiSensorRecT

Value

Num

MOTHPI_SENSOR_NUM_DOMAIN_CONNECTION

Type

SAHPI_CHASSIS