Example applications – Artesyn System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User's Guide (June 2014) User Manual

Page 107

Advertising
background image

Example Applications

System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)

107

-x additionally output the IPMI boot paramater as hexdump

-V print version information and exit

-h display this help and exit

#------------------------------#

# hpichassisstatus

#------------------------------#

Usage: hpichassisstatus [OPTION]...

HPI example application to display the control state of the chassis status

control.

Options:

-d DOMAIN_ID use domain with id DOMAIN_ID

-D walk recursivly through DRT

-r RESOURCE_ID use resource with id RESOURCE_ID

-V print version information and exit

-h display this help and exit

#------------------------------#

# hpicooling

#------------------------------#

Usage: hpicooling [OPTION]...

HPI example application to control the cooling mode.

Note: Only applicable if the HPI daemon runs in Shelf Manager mode.

Options:

-d DOMAIN_ID use domain with id DOMAIN_ID

-D walk recursivly through DRT

-r RESOURCE_ID use resource with id RESOURCE_ID

Advertising