7 serial over lan configuration, Table 4-51, Fan resource - control state – Artesyn System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User's Guide (June 2014) User Manual

Page 87: Serial over lan configuration, Using hpi-b

Advertising
background image

Using HPI-B

System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)

87

4.7

Serial Over LAN Configuration

The ATCA-MF106 and SAM-1411 has the capability to automatically configure the Serial Over
LAN (SOL) feature as specified for IPMI V2.0. The SOL feature, for example, allows you to view
the boot process and the BIOS settings of a blade and to change BIOS settings if necessary.

Whenever a front blade is discovered in the shelf, the ATCA-MF106/SAM-1411 checks whether
the blade supports SOL. If it does support SOL, the ATCA-MF106/SAM-1411 performs all
configuration steps necessary to use the SOL feature.

This includes the following:

1. Configure an IPMI user

2. Configure user privileges

3. Configure LAN channel parameters

4. Configure SOL parameters

The most significant parameters to configure are the IP addresses of the LAN channels. These
are calculated according to the following formula:

LAN channel IP address = <shelf IP address> +<LAN channel> * <configurable multiplier> +
0.0.0.<10*logical slot> + <configurable offset>

TypeUnion.Analog.Default

Default blower speed level

DefaultMode.Mode

SAHPI_CTRL_MODE_AUTO

DefaultMode.ReadOnly

SAHPI_TRUE

WriteOnly

SAHPI_FALSE

Table 4-51 Fan Resource - Control State

SaHpiCtrlStateT

Value

Type

SAHPI_CTRL_TYPE_ANALOG

StateUnion.Analog

Current blower speed level

Table 4-50 Fan Resource - Control (continued)

SaHPICtrlRecT

Value

Advertising